Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (99)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (194)
- (1)
- (3)
- (22)
- (76)
- (185)
- (51)
- (126)
- (1)
- (1)
- (46)
- (14)
- (95)
- (18)
- (2)
- (22)
- (26)
- (6)
- (1)
- (4)
- (3)
- (4)
- (4)
- (11)
- (18)
- (8)
- (55)
- (145)
- (62)
- (3)
- (40)
- (225)
- (46)
- (18)
- (28)
- (8)
- (111)
- (31)
- (20)
- (55)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (16)
- (1)
- (6)
- (25)
- (28)
- (1)
- (1)
- (2)
- (80)
- (5)
- (1)
- (1)
- (36)
- (1)
- (1)
- (810)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (389)
- (309)
- (6)
- (3)
- (134)
- (633)
- (59)
Filtered Search Results
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.5 μm
Hydrophobic membrane with laminated backing for easier handling
| Pore Size | 0.45 μm |
|---|---|
| Bubble Point | 7 psi |
| Flow Rate | 60 mL/min x cm2 |
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Clarification of Acids, Bases and Solvents; Clarification of Alcohol Solutions; UV Spectroscopy. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 8.0 L/min/cm2 |
MilliporeSigma™ PVC Membrane Filters, 5 μm
For air monitoring applications to analyze silica, carbon black or quartz particulates
Cytiva Whatman™ 3 μm Pore Size (ME 29) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 29) Mixed Cellulose Ester Membranes, Plain are particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 3 μm |
|---|---|
| Flow Rate | 1.2 sec./100 mL/12.5 cm² (at Δp = 0.9 bar) |
| Material (Membrane) | ME 29 |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 6.7 sec./100 mL (at Δp = 3 mbar) |
| Thickness (Metric) | 190 μm |
|---|---|
| Pore Size | 1.2 μm |
| Bubble Point | ≥0.4 bar, air with water |
| Flow Rate | Avg. 175 mL/min x cm2 (typical results @ 10 psi);687 mL/min x cm2/psi |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | Nylon |
| Filter Type | Screen Filter |
| No. per Pack | 100Pack. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.45 μm
Hydrophobic membrane with laminated backing for easier handling
| Pore Size | 0.45 μm |
|---|---|
| Bubble Point | 7 psi |
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Diameter (Metric) | 47 mm |
| Color | White |
| Quantity | 100/Pk. |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Clarification of Acids, Bases and Solvents; Clarification of Alcohol Solutions; UV Spectroscopy. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 8.0 L/min/cm2 |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 1.2 μm, Gridded
Mixed cellulose esters (MCE) membrane, hydrophilic
Cytiva Whatman™ Non-Sterile Cellulose Nitrate Membranes
Narrow pore size distribution for improved surface capture and analysis.
Cytiva GN Metricel™ Membrane Disc Filters
Certified for the microbiological analysis of potable, waste, process, and natural waters in accordance with the Membrane Filter Technique referenced in Standard Methods for the Examination of Water and Wastewater.
MilliporeSigma™ Isopore™ Membrane Filters, 0.6 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.
| Pore Size | 0.6 μm |
|---|---|
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
| Sterility | Non-sterile |
| Bubble Point | 8.5 psi |
| Flow Rate | Avg. 43 mL/min x cm2 (typical results (at 10 psi);62 mL/min x cm2/psi) |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
| Gas Flow Rate | 10.0 L/min/cm2 |
Cytiva Whatman™ Sterile Mixed Cellulose Ester Gridded Membranes
Composed of cellulose acetate and cellulose nitrate.
| Pore Size | 0.8 μm |
|---|---|
| Type | Membra Clear Membrane |
| Material | MCE |
| No. per Pack | 100Pack |
Cytiva Whatman™ 90 mm Nuclepore™ Polycarbonate Track-Etched Membranes
Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.
| Flow Rate | High |
|---|---|
| Diameter (Metric) | 90 mm |
| Material | Nucleopore Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Epifluorescence microscopy, environmental analysis, cell biology |
Cytiva Whatman™ Nuclepore™ Hydrophilic Membrane
A highly defined pore size cutoff in the sub-micron range enables particle deformity measurements, and the capture of extremely small particles
| Type | Track Etched Hydrophilic Membrane Filters |
|---|---|
| Shape | Circle |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Bioassays, Cell Biology and Environment Analysis |
| Membrane Type | Polycarbonate Film Track-Etched (PFTE) |
Sartorius Microsart™ @Filter 250 in Bags
Membrane filters suitable for use in the Microsart @Filter units
| Disposable | Single-use |
|---|---|
| Type | Filter Tip |
| Format | Disc |
| Diameter (Metric) | 47 mm |
| Material (Membrane) | Cellulose Nitrate |
| Sample Volume | 250 mL |
| Material | Cellulose Nitrate |
| Sterility | Sterile |